+ | EMC’s Isilon storage is the primary storage platform for the high-performance computing environment. The storage environment provides home and mass storage for the HPC environment with a total capacity of over 1 PB. The storage platform provides scale out NAS storage that delivers increased performance for file based data applications and workflows. In addition EMC’s VNX storage platform is the primary storage environment on campus for virtualized server environments as well as campus data enterprise shares. EMC’s VNX platform is a tiered, scalable storage environment for file, block and object storage. This storage solution is deployed in the enterprise data center with the associated controller, disk, network and power redundancy. | ||
+ | |||
+ | Data Center HVAC Solution consist of has three (3) 30 Ton HVAC units deployed in an N+1 redundancy deployment. Racks of server and computational hardware are arranged in alternating hot and cold aisle configuration. The HVAC units are deployed on a raised floor arrangement with perforated tiles in the cold aisles which allows for superior environmental controls and maintaining the data center at the desired and optimal temperature levels. Optimized performance of chillers in data center is critical for environment control and for this reason the main data center has a 45 Ton chiller installed to facilitate ventilation and air conditioning. In addition ITS has an additional fourteen (14) above the rack cooling units complement the main HVAC units. These above the rack cooling units do not take any additional rack space in the data center. These units are designed to draw hot air from the computational equipment racks and hot aisles and then dissipate conditioned cold air down the cold aisle. This solution provides for an energy efficient cooling solution with zero floor space requirements. | ||
+ | |||
+ | = Network Communication Infrastructure = | ||
+ | Old Dominion University network communication infrastructure is designed using the state of the art networking and switching hardware platforms. The campus infrastructure backbone is fully redundant and capable of 10Gbps data rates between all distribution modules. The data center infrastructure is designed to operate at 40Gbps data rates between the server and storage platforms. | ||
+ | |||
+ | DWDM E-LITE Infrastructure Old Dominion University manages the Eastern Lightwave Integrated Technology Enterprise (E-LITE) infrastructure, which provides 10Gbps connectivity to a number of regional institutions to include the College of William & Mary, Jefferson Lab, Old Dominion University, and the Virginia Modeling, Analysis, and Simulation Center (VMASC). E-LITE infrastructure is designed in a physical ring around the Hampton Roads area providing protected 10Gbps connectivity between the member sites and other national networks like MARIA, Energy Science Network and Internet2. E-LITE network and connectivity to MARIA is being redesigned to upgrade the local DWDM ring to be 100Gbps capable as well as establishment of 100Gbps connection to Internet2. Old Dominion University recently completed a major upgrade on the core server distribution to integrate Nexus 7000 hardware. Nexus 7000 platforms are Cisco Systems next generation switching platforms that are designed for the data center to provide virtualized hardware, in-service upgrades, higher 10Gbps and 40Gbps density, higher performance and reliability. These platforms also provide capability to integrate 100Gbps interfaces in the data center infrastructure as needed. Cisco Nexus platforms include 7000 and 5000 series that provide a higher bandwidth and reliable backbone infrastructure for critical services using technologies such as virtual port channels. | ||
+ | |||
+ | Data Center UPS Batteries for HPC and Network infrastructure consist of a (uninterrupted power supply) UPS system rated at 375KWatts. This unit allows for considerable capacity needed for switching between commercial electrical power and dedicated building power generator. The current UPS system utilizes high performance insulated gate bipolar transistors to provide for larger power capabilities, high speed switching and lower control power consumption. | ||
+ | |||
+ | Campus Virtualized Network Infrastructure. The virtualized network infrastructure supports the unique requirements of University business operations, research, scholarly activities, and online course delivery. Course delivery technologies include video streaming and video conferencing. The Campus Network Virtualization is an initiative that was implemented in the campus environment to make sure we enable our network infrastructure to provide the following features: (i) Communities of interests (Virtual Networks). This will allow us to create network based user communities that have the same functions and communication/application needs. This is being accomplished by using MPLS technology. (ii) High performance and redundant security infrastructure. Security is an important part of any network infrastructure. We have to ensure that users are able to perform all their needed tasks on the network while at the same time have the best possible security protection in place. (iii) Flexibility to provision independent network infrastructures. This feature allows us to create smaller independent logical networks on the existing physical infrastructure. This is of great benefit in a research institution of ODU’s stature and will allow us to work with researchers to provide them the needed resources for their success. |
Revision as of 16:17, 19 March 2019
Contents
Introduction
One of the most notable research programs associated with Old Dominion University is the Center for Real Time Computing (CRTC). The purpose of the CRTC is to pioneer advancements in real-time and large-scale physics-based modeling and simulation computing utilizing quality mesh generation. Since its inception, the CRTC has explored the use of real-time computational technology in Image Guided Therapy, storm surge and beach erosion modeling, and Computational Fluid Dynamics simulations for complex Aerospace applications. The center and its distinguished personnel accomplish their objectives through rigorous theoretical research (which often involves the use of powerful computers) and dynamic collaboration with partners like Harvard Medical School and NASA Langley Research Center in US and Center for Computational Engineering Science (CCES) RWTH Aachen University in Germany and Neurosurgical Department of Huashan Hospital Shanghai Medical College, Fudan University in China. This research is mainly funded from government agencies like ational Science Foundation, National Institute of Health and NASA and philanthropic organizations like John Simon Guggenheim Foundation.
The CRTC is currently under the direction of Professor Nikos Chrisochoides, who has been the Richard T. Cheng Chair Professor at Old Dominion University since 2010. Dr. Chrisochoides’ work in parallel mesh generation and deformable registration for image guided neurosurgery has received international recognition. The algorithms and software tools that he and his colleagues developed are used in clinical studies around the world with more than 40,000 downloads. He has also received significant funding through the National Science Foundation for his innovative research in parallel mesh generation.
CRTC Lab & Resources
To further its mission of fostering research, Old Dominion University has provided the Center for Real Time Computing with lab space in its Engineering and Computational Sciences Building. The CRTC utilizes the lab space and the Department of Computer Science’s other resources to conduct its studies. The principal investigators (PIs) who lead research projects at the CRTC Lab have access to a Dell Precision T7500 workstation, featuring a Dual Six Core Intel Xeon Processor X5690 (total of 12 cores). The processor has a clock speed of 3.46GHz, a cache of 12MB, and QPI speed of 6.4GT/s. The processor also supports up to 96GB of DDR3 ECC SDRAM (6X8GB) at 1333MHz. The system is augmented by the nVIDIA Quadro 6000. With 6 GB of memory, this device provides stunning graphic capabilities. The PIs also have command of an IBM server funded from a NSF MRI award (CNS-0521381), as well as access to the Blacklight system at the Pittsburg Supercomputing Center.
Community Outreach
In addition to research, the lab space and resources of the CRTC may be used for outreach and education activities. Students from the local high school community have visited the lab to view its state-of-the-art equipment and discuss computer science topics with distinguished experts. To continue its outreach to the community, the CRTC will soon make its IBM server available to high school students wishing to gain experience in high performance computing. By granting controlled access of its equipment to interested high school students, the CRTC provides them with an exceptional introduction to computer science work and research, without jeopardizing other research projects. The CRTC also possesses a 3D visualization system, which it uses in its outreach/education programs. This high-quality, interactive system is especially motivating and exciting to high school students stimulated by multi-media.
Information Technology Services (ITS)
Old Dominion University maintains a robust, broadband, high-speed communications network and High Performance Computing (HPC) infrastructure. The facility utilizes 3200 square feet of conditioned space to accommodate server, core networking, storage, and computational resources. The data center has 100+ racks deployed in alternating hot and cold aisle configuration. The data center facility is on raised flooring with minimized obstruction to help facilitate optimized air flow. Some of the monitoring software’s being utilized in the operations center are Solarwinds ORION network performance software and Nagios Infrastructure monitoring application. The IT Operations center monitors the stability and availability of about 400 production servers (physical and virtual), close to 400 network infrastructure switching and routing devices, enterprise storage, and high performance computing resources.
The network is currently comprised of a meshed Ten Gigabit Ethernet backbone supporting voice, data and video with switched 10Gbps connections to the servers and 1Gbps connections to the desktops. Inter-building network connectivity consists of redundant fiber optic data channels yielding high-speed Gigabit connectivity, with Ten-Gigabit connectivity for key building on campus. Ongoing upgrades to Inter-building networks will result in data speeds of 10Gbps for the entire campus. ITS currently provides a variety of Internet services, including 1Gbps connection to Cox communication, 2Gbps connection to Cogent. Connections to Internet2 and Cogent are over a private DWDM regional optical network infrastructure, with redundant 10Gbps links to MARIA aggregation nodes in Ashburn, Virginia and Atlanta, Georgia. The DWDM infrastructure project named ELITE (Eastern Lightwave Internetworking Technology Enterprise) provides access not only to the commodity Internet but gateways to other national networks to include the Energy Science Network and Internet2.
HPC Turing Cluster
The University supports research computing with parallel computing using MPI and OpenMP protocols on compute cluster architectures with shared memory and symmetric multiprocessing compute nodes. Old Dominion University has a high-performance computing cluster named Turing. Researchers have access to high memory nodes and nodes with Xeon Phi co-processors. FDR based infiniband infrastructure provides the communication path for the cluster inter communication. Mass storage is integrated in this cluster at 20Gbps and scratch space is accessible over FDR based infiniband infrastructure. Turing cluster has redundant head nodes and login nodes for increased reliability. The Turing cluster is primarily used by faculty members who are conducting research using software such as Ansys, Comsol, R, Mathematics, and Matlab among other software’s. Integrated in Turing cluster is a number of GPU nodes with NVidia Tesla M2090 GPU’s, to help facilitate computation that requires graphic processors.
Below are the specifications of the Turing cluster as of March, 2019:
Node Type | Total Available Nodes | Maximum Slots (Cores) per node | Additional Resource | Memory (RAM) per node |
Standard Compute | 220 | 16 - 32 | none | 128 GB |
GPU | 21 | 28 - 32 | Nvidia K40, K80, P100, V100 GPU(s) | 128 GB |
Xeon Phi | 10 | 20 | Intel 2250 Phi MICs | 128 GB |
High Memory | 7 | 32 | none | 512 GB - 768 GB |
More details can be found here
EMC’s Isilon storage is the primary storage platform for the high-performance computing environment. The storage environment provides home and mass storage for the HPC environment with a total capacity of over 1 PB. The storage platform provides scale out NAS storage that delivers increased performance for file based data applications and workflows. In addition EMC’s VNX storage platform is the primary storage environment on campus for virtualized server environments as well as campus data enterprise shares. EMC’s VNX platform is a tiered, scalable storage environment for file, block and object storage. This storage solution is deployed in the enterprise data center with the associated controller, disk, network and power redundancy.
Data Center HVAC Solution consist of has three (3) 30 Ton HVAC units deployed in an N+1 redundancy deployment. Racks of server and computational hardware are arranged in alternating hot and cold aisle configuration. The HVAC units are deployed on a raised floor arrangement with perforated tiles in the cold aisles which allows for superior environmental controls and maintaining the data center at the desired and optimal temperature levels. Optimized performance of chillers in data center is critical for environment control and for this reason the main data center has a 45 Ton chiller installed to facilitate ventilation and air conditioning. In addition ITS has an additional fourteen (14) above the rack cooling units complement the main HVAC units. These above the rack cooling units do not take any additional rack space in the data center. These units are designed to draw hot air from the computational equipment racks and hot aisles and then dissipate conditioned cold air down the cold aisle. This solution provides for an energy efficient cooling solution with zero floor space requirements.
Network Communication Infrastructure
Old Dominion University network communication infrastructure is designed using the state of the art networking and switching hardware platforms. The campus infrastructure backbone is fully redundant and capable of 10Gbps data rates between all distribution modules. The data center infrastructure is designed to operate at 40Gbps data rates between the server and storage platforms.
DWDM E-LITE Infrastructure Old Dominion University manages the Eastern Lightwave Integrated Technology Enterprise (E-LITE) infrastructure, which provides 10Gbps connectivity to a number of regional institutions to include the College of William & Mary, Jefferson Lab, Old Dominion University, and the Virginia Modeling, Analysis, and Simulation Center (VMASC). E-LITE infrastructure is designed in a physical ring around the Hampton Roads area providing protected 10Gbps connectivity between the member sites and other national networks like MARIA, Energy Science Network and Internet2. E-LITE network and connectivity to MARIA is being redesigned to upgrade the local DWDM ring to be 100Gbps capable as well as establishment of 100Gbps connection to Internet2. Old Dominion University recently completed a major upgrade on the core server distribution to integrate Nexus 7000 hardware. Nexus 7000 platforms are Cisco Systems next generation switching platforms that are designed for the data center to provide virtualized hardware, in-service upgrades, higher 10Gbps and 40Gbps density, higher performance and reliability. These platforms also provide capability to integrate 100Gbps interfaces in the data center infrastructure as needed. Cisco Nexus platforms include 7000 and 5000 series that provide a higher bandwidth and reliable backbone infrastructure for critical services using technologies such as virtual port channels.
Data Center UPS Batteries for HPC and Network infrastructure consist of a (uninterrupted power supply) UPS system rated at 375KWatts. This unit allows for considerable capacity needed for switching between commercial electrical power and dedicated building power generator. The current UPS system utilizes high performance insulated gate bipolar transistors to provide for larger power capabilities, high speed switching and lower control power consumption.
Campus Virtualized Network Infrastructure. The virtualized network infrastructure supports the unique requirements of University business operations, research, scholarly activities, and online course delivery. Course delivery technologies include video streaming and video conferencing. The Campus Network Virtualization is an initiative that was implemented in the campus environment to make sure we enable our network infrastructure to provide the following features: (i) Communities of interests (Virtual Networks). This will allow us to create network based user communities that have the same functions and communication/application needs. This is being accomplished by using MPLS technology. (ii) High performance and redundant security infrastructure. Security is an important part of any network infrastructure. We have to ensure that users are able to perform all their needed tasks on the network while at the same time have the best possible security protection in place. (iii) Flexibility to provision independent network infrastructures. This feature allows us to create smaller independent logical networks on the existing physical infrastructure. This is of great benefit in a research institution of ODU’s stature and will allow us to work with researchers to provide them the needed resources for their success.